Installation, Operation and Maintenance Manual
11. Install the RO Assembly and Storage Tank
Under counter Installation:
The RO assembly is usually mounted to the right or left sink cabinet sidewall, taking into consideration the
space available and the tank location. Generally, the tank is placed in the rear of the sink cabinet while the
RO assembly is positioned toward the front for better accessibility.
TomounttheROassembly,elevateitatleast2”offthecabinetoor(withcartridgesinstalled)and,while
keepinglevel,markthelocationofthemountingholesonthecabinetsidewall.Makesmallpilotholeswith
an awl or drill and screw in the two mounting screws, leaving just enough protruding to allow bracket mount-
ing slots to slide over them.
NOTE:Ifthecabinetsidewallsarenotofsolidconstruction,theROassemblycanbesetonthecabinet
oorandheldagainstthesidewallwiththemountingscrews.However,theROassemblywillthenneedto
be lifted from the mounting screws in order to remove filter cartridges.
The tank can be oriented either vertically or horizontally. It is generally placed to the rear of the cabinet but
canbesetinthefromcenter(betweenthesinkbasins)foreaseofaccessifspacepermits.
Basement Installation:
TheROassemblyisgenerallymountedtothebasementwall(usingwallanchors)ortowoodceilingsup-
ports. To mount the RO assembly, keep bracket level and mark the location of the mounting holes. Install
wall anchors and/or mounting screws as required. Leave screw heads protruding to allow bracket mounting
slots to slide over them.
Thetankmaybeorientedeitherverticallyorhorizontallyandcanbeplacedonashelf,ontheoor,orsus-
pended from the ceiling supports using sturdy brackets.
An effort should be made to minimize the distance between the tank and RO assembly to help assure an
adequateowratetothefaucet.
12. Make Final Tubing Connections (see Figure 1)
With all of the components in place, the final tubing connections can be made. When routing tubing be-
tween components, several guidelines should be observed.
Tubing runs should generally follow the contour of the cabinets rather than interfere with the cabinet stor-
agearea.Striveforneatnessandanorderlytubing“ow”usingfasteners(e.g.insulatedstaples)tosecure
thetubing.Arrangethetubingsotherearenosharpbendsandleavesome“play”inthetubingforeaseof
servicing, then cut tubing to desired length.
TrytokeepthetubingfromtheROassemblytothetankandfaucetasshortaspracticalforgoodow.
Undersink Installation:
A)Connectorange1/4”tubingfromfeedwatervalveto“Feed”connectiononROassembly.
B)Connectoneendofblue3/8”tubingtofaucetadapterandtheotherendtothe“faucet”connectionon
the RO assembly.
C)Connectyellow3/8”tubingfromstoragetanktotheteeontheROassembly.
D)Routespecialred“SFC”tubefromROassemblymodule(factorymadeconnection)towardfaucet.Do
not cut this special SFC tube. Its length is important to maintain proper efficiency and performance.
E)RemovewhiteplugfromcouplingttingonendofredSFCtube.ConnectSFCtubetooneendof1/4”
x1/4”couplingtting.
F) Connectthegreen1/4”tubingfromfaucetairgapto1/4”couplingttingontheendofSFCtube
(SeeFigure4onpage17).
10
To reduce the risk associated with a hazardous voltage due to an installer drilling through existing electric
wiring or water pipes in the area of installation:
•Do not install near electric wiring or piping which may be in the path of a drilling tool when selecting the position
to mount the filter bracket.